HV 2
Small water supply, washing
- Rated flow
- 2 m³/h
- Head
- 21–102 m
- Stages
- 4·8·14
- Motor
- 0.37–1.1 kW
- Connection
- 25A

Design exampleA website design example with a fictional brand · company, models, figures and contacts are fictional
Vertical multistage pumps for water supply, cooling and process water · since 2004
From booster sets in high-rise buildings to cooling loops and washing lines. We machine the shafts and impellers, assemble each pump and run it on our test bench before it ships with its own test certificate in English.
About us
HAESOL PUMP started in 2004 as a pump repair and assembly shop in Suwon. Since moving to Hwaseong in 2015 we have made only one product line, the HV series of vertical multistage pumps. Fourteen of our 32 staff work in machining, assembly and testing. Fictional company data

Sizes are set by rated flow, and each size comes with three stage counts to cover the head. Pumps of the same size share the body and pipe connections, so you can change the stage count without changing the pipework.

Small water supply, washing
Small building water supply
Mid-size buildings, boiler feed
Apartment and office boosting
Large complexes, cooling water
Cooling loops, high-flow process water
Suction and discharge sit in line, so the pump drops straight into the pipe run and takes little floor space. Most of our pumps go into building plant rooms and factory utilities.

Booster sets for apartments and offices. Head and flow come from building height and peak demand.

Cooling tower and boiler secondary circuits. Liquid temperature −15 to 120 °C.

From the feed tank to the boiler. With hot water we check suction conditions (NPSH) separately.

Factory washing lines and membrane filtration feed. Wetted parts in AISI 304, or 316L where needed.
Not forfire fighting (needs separately approved pumps), flammable liquids, sewage with solids, or direct transfer of food ingredients. If you are not sure, put the liquid and its temperature in your enquiry.
All photos are example images.
Every pump runs on the factory test bench before it leaves, and the results go with it as a test certificate. Witness tests can be booked one week ahead, in person or by live video.

Impellers and shafts are CNC machined. Impeller diameter and shaft runout are measured on every part.

Impellers and diffusers are stacked stage by stage, the shaft height is set and the cartridge seal goes in.

Flow, head and current are measured on the bench, and the pump is pressure-tested at 1.5 times its maximum working pressure.
All photos are example images.
| Test | Scope | Criteria |
|---|---|---|
| Performance (flow, head, current) | Every pump | 3 points including the rated point, issued as a test certificate |
| Hydrostatic | Every pump | 1.5 × maximum working pressure for 3 minutes, no leakage |
| Vibration and noise | Every pump | Measured values stated on the certificate |
| NPSH | Type test per model | For new models and design changes |
Motors are bought in from Korean motor makers. The efficiency class is the one on the motor nameplate, and the motor test report is sent on request.
Engineering tools for consultants, contractors and plant engineers. Open up the pump to follow the water and the seal replacement, or pick a model for your flow and head, at 50 or 60 Hz, in metric or US units. For preliminary selection only; our engineer confirms the final selection against your system.
How water goes in and out, and the order in which you open the pump to change the seal. The drawing is redrawn from the stage count, pipe size and motor size of the model you pick.
Cross-section of a vertical multistage pump. The front quarter is cut away to show impellers and diffusers stacked stage by stage inside the outer sleeve.
Key point: each stage adds a fixed amount of head, so stacking stages adds head. Steps and tools are in chapter 7 of the IOM manual.
Instead of site names and savings claims, we show which conditions led to which model, and why. Fictional cases for this design example · not real sites

Night demand drops below a third of the daytime peak, so we chose VFD operation that slows the pumps down. The standby pump keeps water flowing during maintenance.

The single-stage model falls short of head at 60 m³/h, so we went to two stages and trimmed the surplus head with speed. In a closed loop the required head drops together with the flow.

Because of the detergent, wetted parts were changed to 316L. The line always runs at the same flow, so a model close to its rated point runs at fixed speed.
Put these conditions into the model finder at 60 Hz and the same models come up. Photos are example images.
The model finder and the cross-section read these numbers directly. The full performance data is available as a CSV file.
Fictional data · for calculation practice HV series, 18 standard models · test conditions: clean water 20 °C, 60 Hz, 3,500 rpm. At 50 Hz (2,900 rpm) flow is about ×0.83, head ×0.69 and shaft power ×0.57.
| Model | Stages | Rated flowm³/h | Rated headm | Shut-off headm | Best efficiency% | Shaft power at rated pointkW | MotorkW | Connection | NPSHrm |
|---|---|---|---|---|---|---|---|---|---|
| HV 2-4 | 4 | 2 | 24 | 31 | 50 | 0.26 | 0.37 | 25A | 1.5 |
| HV 2-8 | 8 | 2 | 48 | 62 | 50 | 0.52 | 0.75 | 25A | 1.5 |
| HV 2-14 | 14 | 2 | 84 | 108.5 | 50 | 0.92 | 1.1 | 25A | 1.5 |
| HV 4-3 | 3 | 4 | 22.5 | 29 | 58 | 0.42 | 0.55 | 32A | 1.8 |
| HV 4-6 | 6 | 4 | 45 | 58 | 58 | 0.85 | 1.1 | 32A | 1.8 |
| HV 4-12 | 12 | 4 | 90 | 116 | 58 | 1.69 | 2.2 | 32A | 1.8 |
| HV 8-2 | 2 | 8 | 20 | 25.6 | 65 | 0.67 | 1.1 | 40A | 2.2 |
| HV 8-5 | 5 | 8 | 50 | 64 | 65 | 1.68 | 2.2 | 40A | 2.2 |
| HV 8-10 | 10 | 8 | 100 | 128 | 65 | 3.35 | 5.5 | 40A | 2.2 |
| HV 16-2 | 2 | 16 | 27.5 | 35 | 70 | 1.71 | 2.2 | 50A | 2.8 |
| HV 16-4 | 4 | 16 | 55 | 70 | 70 | 3.43 | 5.5 | 50A | 2.8 |
| HV 16-8 | 8 | 16 | 110 | 140 | 70 | 6.85 | 11 | 50A | 2.8 |
| HV 32-1 | 1 | 32 | 16.7 | 21.3 | 74 | 1.97 | 3.7 | 65A | 3.5 |
| HV 32-3 | 3 | 32 | 50 | 64 | 74 | 5.89 | 7.5 | 65A | 3.5 |
| HV 32-6 | 6 | 32 | 100 | 128 | 74 | 11.78 | 15 | 65A | 3.5 |
| HV 64-1 | 1 | 64 | 22.5 | 29 | 76 | 5.16 | 7.5 | 100A | 4.5 |
| HV 64-2 | 2 | 64 | 45 | 58 | 76 | 10.33 | 15 | 100A | 4.5 |
| HV 64-4 | 4 | 64 | 90 | 116 | 76 | 20.65 | 30 | 100A | 4.5 |
Each cell: flow (m³/h), then head · efficiency · shaft power. Curve H = H₀ − (H₀ − H rated)(Q/Q rated)², efficiency η = η best × (2r − r²), r = Q/Q rated. 1 m³/h = 4.403 US gpm, 1 m = 3.281 ft.
| Model | 0% | 50% | 75% | Rated | 120% |
|---|---|---|---|---|---|
| HV 2-4 | 031 m · — | 129.3 m · 37.5% · 0.21 kW | 1.527.1 m · 46.9% · 0.24 kW | 224 m · 50% · 0.26 kW | 2.420.9 m · 48% · 0.29 kW |
| HV 2-8 | 062 m · — | 158.5 m · 37.5% · 0.43 kW | 1.554.1 m · 46.9% · 0.47 kW | 248 m · 50% · 0.52 kW | 2.441.8 m · 48% · 0.57 kW |
| HV 2-14 | 0108.5 m · — | 1102.4 m · 37.5% · 0.74 kW | 1.594.7 m · 46.9% · 0.83 kW | 284 m · 50% · 0.92 kW | 2.473.2 m · 48% · 1.00 kW |
| HV 4-3 | 029 m · — | 227.4 m · 43.5% · 0.34 kW | 325.3 m · 54.4% · 0.38 kW | 422.5 m · 58% · 0.42 kW | 4.819.6 m · 55.7% · 0.46 kW |
| HV 4-6 | 058 m · — | 254.8 m · 43.5% · 0.69 kW | 350.7 m · 54.4% · 0.76 kW | 445 m · 58% · 0.85 kW | 4.839.3 m · 55.7% · 0.92 kW |
| HV 4-12 | 0116 m · — | 2109.5 m · 43.5% · 1.37 kW | 3101.4 m · 54.4% · 1.52 kW | 490 m · 58% · 1.69 kW | 4.878.6 m · 55.7% · 1.85 kW |
| HV 8-2 | 025.6 m · — | 424.2 m · 48.8% · 0.54 kW | 622.4 m · 60.9% · 0.60 kW | 820 m · 65% · 0.67 kW | 9.617.5 m · 62.4% · 0.74 kW |
| HV 8-5 | 064 m · — | 460.5 m · 48.8% · 1.35 kW | 656.1 m · 60.9% · 1.51 kW | 850 m · 65% · 1.68 kW | 9.643.8 m · 62.4% · 1.84 kW |
| HV 8-10 | 0128 m · — | 4121 m · 48.8% · 2.71 kW | 6112.3 m · 60.9% · 3.01 kW | 8100 m · 65% · 3.35 kW | 9.687.7 m · 62.4% · 3.68 kW |
| HV 16-2 | 035 m · — | 833.1 m · 52.5% · 1.38 kW | 1230.8 m · 65.6% · 1.53 kW | 1627.5 m · 70% · 1.71 kW | 19.224.2 m · 67.2% · 1.88 kW |
| HV 16-4 | 070 m · — | 866.3 m · 52.5% · 2.75 kW | 1261.6 m · 65.6% · 3.07 kW | 1655 m · 70% · 3.43 kW | 19.248.4 m · 67.2% · 3.77 kW |
| HV 16-8 | 0140 m · — | 8132.5 m · 52.5% · 5.50 kW | 12123.1 m · 65.6% · 6.14 kW | 16110 m · 70% · 6.85 kW | 19.296.8 m · 67.2% · 7.54 kW |
| HV 32-1 | 021.3 m · — | 1620.1 m · 55.5% · 1.58 kW | 2418.7 m · 69.4% · 1.76 kW | 3216.7 m · 74% · 1.97 kW | 38.414.7 m · 71% · 2.16 kW |
| HV 32-3 | 064 m · — | 1660.5 m · 55.5% · 4.75 kW | 2456.1 m · 69.4% · 5.29 kW | 3250 m · 74% · 5.89 kW | 38.443.8 m · 71% · 6.46 kW |
| HV 32-6 | 0128 m · — | 16121 m · 55.5% · 9.51 kW | 24112.3 m · 69.4% · 10.58 kW | 32100 m · 74% · 11.78 kW | 38.487.7 m · 71% · 12.92 kW |
| HV 64-1 | 029 m · — | 3227.4 m · 57% · 4.19 kW | 4825.3 m · 71.3% · 4.65 kW | 6422.5 m · 76% · 5.16 kW | 76.819.6 m · 73% · 5.63 kW |
| HV 64-2 | 058 m · — | 3254.8 m · 57% · 8.38 kW | 4850.7 m · 71.3% · 9.31 kW | 6445 m · 76% · 10.33 kW | 76.839.3 m · 73% · 11.27 kW |
| HV 64-4 | 0116 m · — | 32109.5 m · 57% · 16.75 kW | 48101.4 m · 71.3% · 18.61 kW | 6490 m · 76% · 20.65 kW | 76.878.6 m · 73% · 22.53 kW |
| Part | S version | L version |
|---|---|---|
| Impellers, diffusers | AISI 304 | AISI 316L |
| Outer sleeve | AISI 304 | AISI 316L |
| Shaft | AISI 431 | AISI 316 |
| Base, pump head | Cast iron EN-GJL-250 (painted) | Cast stainless 316 |
| Mechanical seal | Carbon / SiC · EPDM | SiC / SiC · FKM |
Drawings are sent to your company email address. The CSV of the performance data is generated right here from the table on this page.
| Document | Format | Size | Revision | Get |
|---|---|---|---|---|
| HV Series Catalogue (English) | 4.0 MB | 2026-09 | Request | |
| Dimension drawings by model | DWG · STEP | Per model | 2026-06 | Request |
| Installation, operation and maintenance manual (English) | 2.8 MB | 2026-03 | Request | |
| Sample test certificate (English) | 0.3 MB | 2026-09 | Request | |
| Performance data (same values as this page) | CSV | about 4 KB | 2026-09 |
This is an example page, so there are no PDF or drawing files. The request buttons lead to the quotation form.
What you can expect when you order from outside Korea. Ask for anything not listed here and our export team will answer in English. Fictional terms for this design example
3-phase motors for 380–415 V 50 Hz or 380–460 V 60 Hz. Single-phase up to 1.1 kW on request. Tell us your supply and we quote the matching motor; the efficiency class is the one on its nameplate.
T/T with 30% advance and 70% before shipment, or an irrevocable L/C at sight. Quotations are in USD unless you ask for another currency, and are valid for 30 days.
Vertical multistage centrifugal pumps are usually classified under HS 8413.70. Your customs broker confirms the final code for your country.
Distributors wantedWe are looking for distributors who can hold stock and service pumps locally, especially in the Middle East, Southeast Asia and Central Asia. Choose "Distributor enquiry" in the form below.
Standard models are kept in stock. Changing stages, motor or material makes it an assembled model, and anything that needs drawing approval is a custom build. Lead times below are ex-works; FOB Busan adds about one week for export packing and documents.
| Type | Lead time (ex-works) | Covers |
|---|---|---|
| Stock model | Ships in 3 business days | 18 standard models, S material, 60 Hz motor |
| Assembled model | 2 weeks | Different stages, 50 Hz or other motors, L material |
| Custom build | 4–6 weeks after drawing approval | Special materials or connections, project documents |
12 months from installation or 18 months from shipment, whichever ends first. Not covered: operation outside the allowed range (including dry running), liquids not agreed in the order, and normal wear of seals and O-rings.
Our distributors service pumps where we have one. Elsewhere we troubleshoot with you by video call in English and send parts by air courier. A recommended spare parts list comes with every order.
Seals, impellers and bearings remain available for seven years after a model is discontinued. Send us the serial number from the nameplate and we find the right part.
The price of the same model changes a lot with material, motor, documents, quantity and delivery terms, so we quote in writing once we have your conditions.
Machining, assembly and testing happen in our Hwaseong factory. Castings, motors and seals come from specialist suppliers. Here is exactly what we do ourselves.
A pump runs for a long time once it is installed. So we show you the numbers you need before you choose, and after you choose, we make sure the parts never run out.
| Name | HAESOL PUMP Co., Ltd. |
|---|---|
| Founded | 2004 |
| Factory | Hwaseong, Gyeonggi-do, Korea (fictional address) |
| Products | HV series vertical multistage centrifugal pumps |
| Main line | +82-31-000-0000 (Mon–Fri 08:30–17:30 KST) |
| [email protected] |
| For | Contact | Phone | Reply | |
|---|---|---|---|---|
| Export sales (English) | Seojin Park, Export team | +82-31-000-0002 | [email protected] | Within 2 business days |
| Technical questions | Doyun Kim, Sales engineering | +82-31-000-0001 | [email protected] | By 17:00 KST next business day |
| Service and spare parts | Junho Lee, Service team | +82-31-000-0003 | [email protected] | Same-day acknowledgement |

What buyers and engineers abroad ask us most before they request a quotation.
Yes. The data table is at 60 Hz (3,500 rpm). At 50 Hz the pump turns at about 2,900 rpm, so flow drops to about 83%, head to about 69% and shaft power to about 57%. Select 50 Hz in the model finder to see the converted curves, and we quote a 50 Hz motor as an assembled model.
No, standard models can be ordered one at a time. For distributor orders and projects we quote quantity prices.
Commercial invoice, packing list, bill of lading or air waybill, certificate of origin, an English test certificate for every pump and the English IOM manual. Tell us early if your project needs other documents, such as material certificates.
Yes, in person at the factory or by live video. Book one week ahead and we run the pump at the points you choose.
It uses the performance data at test conditions (clean water 20 °C, rated speed) and a simple system curve. In reality pipe losses, valve position, liquid temperature and motor efficiency change the result. Our engineer recalculates against your system before the final selection.
Send us a photo of the old pump's nameplate and the pipe size. We find a model that works at the same duty point, and if the connection height differs we give you the adapter dimensions.
Order the recommended spare parts list with the pumps, and keep seal kits on site. Other parts are shipped by air courier.
Requirements depend on the country and application, so we confirm them per model and destination at the quotation stage. Tell us where the pump will be installed and what it will pump.
Flow and head are enough to start. Our export team replies within 2 business days (KST) with a written quotation or follow-up questions, in English.

아래 신청서를 남겨 주시면 이메일로 상담 회신드립니다.
메일로 바로 문의: support@uriui.com · 카카오톡 상담